• ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing Plastic
  • ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing Plastic
  • ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing Plastic
  • ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing Plastic
  • ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing Plastic
  • ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing Plastic

ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing Plastic

After-sales Service: Online
Warranty: 1 Year
Type: Melt Flow Index Tester
Weight: 66kg
Transport Package: Plywood Case
Specification: 50*60*40cm
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2024

Suppliers with verified business licenses

Hunan, China
Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (6)

Basic Info.

Model NO.
GA-1001-B
Trademark
GONOAVA
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester MVR Tests Device Melt Index Instrument GA-1001-B for Testing Plastic
Product Character:
1.English LCD Touched Screen.Ø
2.Hand and Automatic cutting material.
3.Double temperature control system, temperature control precision is more accurate, higher heating efficienc
4.Double imported sensors, more accurate temperature gradient from top to bottom, can be used independently, and improve the service life.
5. Cylinder for imports hartz alloying nitriding treatment, opening mould for carbon tungsten steel material, material reality.
6.Insulation barrels of sus304 stainless steel material for the whole, long-term high temperature does not rust.
7.Automatic calculation results, and print.
8.Have USB connector,can connect computer.


Standard:
GB/T3682-2000 Determination of melt flow rate and melt volume flow rate of thermoplastics
ISO 1133:1997 Determination of melt flow rate and melt volume flow rate of thermoplastics
ASTM D1238 Standard Test Method for Determination of flow rate of Thermoplastic Melt by extruded plasticizer
Test Methods:MFR+MVR Methods
Display mode: 7-inch touch screen controller


ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester MVR Tests Device Melt Index Instrument GA-1001-B for Testing Plastic
Description:
Used for testing all kinds of plastic, resin in the state of viscous flow through a certain temperature and load, every 10 min module and melt flow rate through the standard port MFR value, it is suitable for high temperature of polycarbonate, aromatic sulfone, fluorine plastic, nylon and other engineering plastics, can also be applied to polyethylene (PE), polystyrene (PS), polypropylene (PP), ABS resin, polyformaldehyde (POM), polycarbonate (PC) resin with lower melting temperature, such as plastic test, widely used in plastic production, plastic products, such as petroleum and chemical industry and related colleges and universities, scientific research units, and the commodity inspection department.


Specification
 
Model GA-1001-B
Loading Barrel parameters Inner hole Φ9.550±0.025mm
Cylinder diameter Φ2.095±0.005mm
 
Outlet length 8.000±0.025mm
Temperature range Room Temperature~450ºC
Temperature fluctuation ±0.2 ºC
Temperature uniformity ±1ºC
Temperature display resolution 0.1ºC
Display resolution  0.1ºC
Time display resolution  0.1s
Displacement accuracy 0.001mm
 
Volume timing accuracy 0.001s
 
Testing scope of mass method 0.1-150g/10min
 
Range of test results by volumetric method 50-5000cm³/10min
 
Weight parameters are as follows:
Weight accuracy  ±0.5%
Basic configuration
 
A    0.325kg  
B    1.2kg
C    2.16kg
D    3.8kg
E     5kg
F     10kg
G    12.5kg
H     21.6kg
Position detection
Loop distance from up and down 30mm
Control precision ± 0.1mm
Test flow control
Times of cutting the material 0~10 times
Material cutting interval 0~999s(set reference Table 2)
Control flow reaches the set temperature without volatility
Barrel temperature time 15 min.
Material be installed 1 min.
Material sample temperature recovery time 4 min.
When binder set 1min
Output mode Micro-automatic print output
Cut material methods Hand and Automatic Cut
Test load Eight sets of weights
Power AC220V±10%   50/60HZ   



Accessories List
 
No Name Qty Remark
1 Weight 1 set 0.325kg,0.875kg,1.835kg,2.5kg,2.915kg,3.475kg,4.615kg,5.0kg
2 Weight tray 1pcs Within level 1 load
3 Charging hopper 1pcs  
4 Mouth mold cleaning rod 1pcs  
5 Charging bar 1pcs  
6 Cylinder cleaning rod 1pcs  
7 piston rod 1pcs  
8 mouth mold 1pcs  
9 gauze 2roll  
10 Print paper 2 roll  



ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester MVR Tests Device Melt Index Instrument GA-1001-B for Testing Plastic
Standard test force(8 level)
1  level:0.325 kg=(piston rod+weight tray+heat insulation cover+No 1 weight)=3.187N
   2  level:1.200 kg=(0.325+No2  0.875 weight)=11.77 N
   3  level:2.160 kg=(0.325+No3  1.835 Weight)=21.18 N
   4  Level:3.800 kg=(0.325+No4  3.475Weight)=37.26 N
   5  Level:5.000 kg=(0.325+No.5  4.675Weight)=49.03 N
   6  Level:10.000 kg=(0.325+No.5  4.675weight+No.6 5.000Weight)=98.07 N
   7  Level:12.000 kg=(0.325+No.5  4.675weight+No.6 5.000+No.7 2.500weight)=122.58 N
   8  level:21.600 kg=(0.325+No.2  0.875weight+No3. 1.835+No.4
 3.475+No.5 4.675+No.6 5.000+No.7 2.500+No.8 2.915weight)=211.82 N


Chart 1
Melt flow rate (g/10min) Sample quality in charging barrel (g) Extrudate cutting-off interval time  (s)
0.1-0.5 3-5 240
>0.5-1 4-6 120
>1-3.5 4-6 60
>3.5-10 6-8 30
>10 6-8 5-15

1. If this experiment value is less than 0.1 g / 10 min or greater than 100 g / 10 min, suggest you melt flow rate
2. When the material density is greater than 1.0 g / 10 min, may need to increase the sample size.
3. With more than 25 g / 10 min. Measuring MFR of material, in order to obtain enough reproducibility, may need to cut the time interval of less than 0.1 s for automatic control and measurement, or use method B.
 



Chart 2
Material Test temperatureθ,ºC    Standard load mnom,kg
PS 200 5.00
PE 190 2.16
PE 190 0.325
PE 190 21.60
PE 190 5.00
PP 230 2.16
ABS 230 10.00
PS-1 200 5.00
E/VAC 150 2.16
E/VAC 190 2.16
E/VAC 125 0.325
SAN 220 10.00
ASA,ACS,AEC 220 10.00
PC 300 1.2
PMMA 230 3.8
PB 190 2.16
PB 190 10.00
POM 190 2.16
MABS 220 10.00

ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing Plastic
ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing Plastic
ISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing PlasticISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing PlasticISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing PlasticISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing PlasticISO 1133 ASTM D1238 Touched Screen Melt Flow Index Tester Mvr Tests Device Melt Index Instrument Ga-1001-B for Testing Plastic

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now